{"title":"Refrigerants","description":"","products":[{"product_id":"r32-freon-refrigerant","title":"20.9LB R32 R-32 Freon Refrigerant Gas","description":"\u003cp data-start=\"173\" data-end=\"569\" class=\"\"\u003eR-32 (Difluoromethane) is a next-generation single-component HFC refrigerant known for its superior energy efficiency and significantly lower Global Warming Potential (GWP) compared to traditional blends like R-410A. With increasing environmental regulations worldwide, R-32 has become the preferred refrigerant in modern air conditioning systems designed for sustainability and high performance.\u003c\/p\u003e \u003chr data-start=\"571\" data-end=\"574\" class=\"\"\u003e \u003ch5 data-start=\"576\" data-end=\"610\"\u003e\u003cstrong data-start=\"580\" data-end=\"610\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"612\" data-end=\"766\" class=\"\"\u003e✅ \u003cstrong data-start=\"614\" data-end=\"635\"\u003eLow GWP solution:\u003c\/strong\u003e R-32 has a GWP of only 675—approximately 70% lower than R-410A—making it a climate-conscious choice for eco-friendly HVAC systems.\u003c\/p\u003e \u003cp data-start=\"768\" data-end=\"930\" class=\"\"\u003e✅ \u003cstrong data-start=\"770\" data-end=\"797\"\u003eHigh energy efficiency:\u003c\/strong\u003e Offers excellent heat transfer and refrigeration capacity, leading to lower electricity consumption and improved system performance.\u003c\/p\u003e \u003cp data-start=\"932\" data-end=\"1088\" class=\"\"\u003e✅ \u003cstrong data-start=\"934\" data-end=\"955\"\u003ePure refrigerant:\u003c\/strong\u003e As a single-component refrigerant, R-32 is easier to recover and recycle, with no glide issues compared to multi-blend refrigerants.\u003c\/p\u003e \u003cp data-start=\"1090\" data-end=\"1268\" class=\"\"\u003e✅ \u003cstrong data-start=\"1092\" data-end=\"1116\"\u003eNext-gen compatible:\u003c\/strong\u003e Supported by many new high-efficiency air conditioning and heat pump systems; ideal for forward-looking installations and retrofits (where applicable).\u003c\/p\u003e \u003chr data-start=\"1270\" data-end=\"1273\" class=\"\"\u003e \u003ch5 data-start=\"1275\" data-end=\"1307\"\u003e\u003cstrong data-start=\"1279\" data-end=\"1307\"\u003eR-32 Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1309\" data-end=\"1506\"\u003e \u003cli data-start=\"1309\" data-end=\"1347\" class=\"\"\u003e \u003cp data-start=\"1311\" data-end=\"1347\" class=\"\"\u003e\u003cstrong data-start=\"1311\" data-end=\"1329\"\u003eChemical Name:\u003c\/strong\u003e Difluoromethane\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1348\" data-end=\"1380\" class=\"\"\u003e \u003cp data-start=\"1350\" data-end=\"1380\" class=\"\"\u003e\u003cstrong data-start=\"1350\" data-end=\"1372\"\u003eMolecular Formula:\u003c\/strong\u003e CH₂F₂\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1381\" data-end=\"1419\" class=\"\"\u003e \u003cp data-start=\"1383\" data-end=\"1419\" class=\"\"\u003e\u003cstrong data-start=\"1383\" data-end=\"1401\"\u003eBoiling Point:\u003c\/strong\u003e -51.7°C (-61°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1420\" data-end=\"1463\" class=\"\"\u003e \u003cp data-start=\"1422\" data-end=\"1463\" class=\"\"\u003e\u003cstrong data-start=\"1422\" data-end=\"1457\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 675\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1464\" data-end=\"1506\" class=\"\"\u003e \u003cp data-start=\"1466\" data-end=\"1506\" class=\"\"\u003e\u003cstrong data-start=\"1466\" data-end=\"1502\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1508\" data-end=\"1511\" class=\"\"\u003e \u003ch5 data-start=\"1513\" data-end=\"1538\"\u003e\u003cstrong data-start=\"1517\" data-end=\"1538\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1540\" data-end=\"1687\" class=\"\"\u003e\u003cstrong data-start=\"1540\" data-end=\"1587\"\u003eResidential and Commercial Air Conditioning\u003c\/strong\u003e\u003cbr data-start=\"1587\" data-end=\"1590\"\u003eUsed in new-generation A\/C systems designed for higher efficiency and lower environmental impact.\u003c\/p\u003e \u003cp data-start=\"1689\" data-end=\"1821\" class=\"\"\u003e\u003cstrong data-start=\"1689\" data-end=\"1703\"\u003eHeat Pumps\u003c\/strong\u003e\u003cbr data-start=\"1703\" data-end=\"1706\"\u003ePopular choice in modern high-performance heat pump systems for both residential and light commercial environments.\u003c\/p\u003e \u003cp data-start=\"1823\" data-end=\"1958\" class=\"\"\u003e\u003cstrong data-start=\"1823\" data-end=\"1850\"\u003eNext-Gen HVAC Equipment\u003c\/strong\u003e\u003cbr data-start=\"1850\" data-end=\"1853\"\u003eAn ideal replacement in systems built to operate with low-GWP refrigerants and advanced safety standards.\u003c\/p\u003e \u003chr data-start=\"1960\" data-end=\"1963\" class=\"\"\u003e \u003ch5 data-start=\"1965\" data-end=\"2017\"\u003e\u003cstrong data-start=\"1969\" data-end=\"2015\"\u003eNote on Environmental \u0026amp; Safety Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"2018\" data-end=\"2270\" class=\"\"\u003eWhile R-32 has no ozone depletion potential and a low GWP, it is classified as A2L (mildly flammable). Proper handling, installation, and ventilation precautions must be observed. Always follow local safety codes and regulations when working with R-32.\u003c\/p\u003e \u003chr data-start=\"2272\" data-end=\"2275\" class=\"\"\u003e \u003ch5 data-start=\"2277\" data-end=\"2292\"\u003e\u003cstrong data-start=\"2281\" data-end=\"2292\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2294\" data-end=\"2562\"\u003e \u003cli data-start=\"2294\" data-end=\"2356\" class=\"\"\u003e \u003cp data-start=\"2296\" data-end=\"2356\" class=\"\"\u003e\u003cstrong data-start=\"2296\" data-end=\"2310\"\u003ePackaging:\u003c\/strong\u003e Net Weight 9.5kg\/bottle (Net Weight 20.9lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2357\" data-end=\"2405\" class=\"\"\u003e \u003cp data-start=\"2359\" data-end=\"2405\" class=\"\"\u003e\u003cstrong data-start=\"2359\" data-end=\"2377\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2406\" data-end=\"2562\" class=\"\"\u003e \u003cp data-start=\"2408\" data-end=\"2562\" class=\"\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2420\"\u003eStorage:\u003c\/strong\u003e Store in a dry, cool, and well-ventilated area. Keep away from open flames and direct sunlight. Handle with appropriate leak-proof equipment.\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562107478364,"sku":"PZ-32","price":245.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/R32_574fb931-38dd-487c-a8bd-43239267a7b3.jpg?v=1778108732"},{"product_id":"r407c-freon-refrigerant","title":"20.9LB R407C R-407C Freon Refrigerant Gas","description":"\u003cp data-start=\"183\" data-end=\"488\" class=\"\"\u003eR-407C is a non-ozone depleting HFC blend developed as a long-term replacement for R-22 in residential and light commercial air conditioning systems. Its similar pressure-temperature characteristics and system compatibility make it an effective retrofit solution that requires minimal system modification.\u003c\/p\u003e \u003chr data-start=\"490\" data-end=\"493\" class=\"\"\u003e \u003ch5 data-start=\"495\" data-end=\"529\"\u003e\u003cstrong data-start=\"499\" data-end=\"529\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"531\" data-end=\"716\" class=\"\"\u003e✅ \u003cstrong data-start=\"533\" data-end=\"554\"\u003eR-22 alternative:\u003c\/strong\u003e Designed to closely match the performance of R-22, R-407C is a great choice for servicing or converting existing systems without needing major equipment changes.\u003c\/p\u003e \u003cp data-start=\"718\" data-end=\"857\" class=\"\"\u003e✅ \u003cstrong data-start=\"720\" data-end=\"745\"\u003eZero ozone depletion:\u003c\/strong\u003e Contains no chlorine, giving it an ODP of 0 and making it compliant with international environmental standards.\u003c\/p\u003e \u003cp data-start=\"859\" data-end=\"1027\" class=\"\"\u003e✅ \u003cstrong data-start=\"861\" data-end=\"888\"\u003eEfficient and reliable:\u003c\/strong\u003e Delivers solid cooling performance in both residential and commercial environments, supporting a broad range of A\/C and heat pump systems.\u003c\/p\u003e \u003cp data-start=\"1029\" data-end=\"1176\" class=\"\"\u003e✅ \u003cstrong data-start=\"1031\" data-end=\"1066\"\u003eWidely available and supported:\u003c\/strong\u003e Compatible with standard HFC components and synthetic POE lubricants, making it easy to service and maintain.\u003c\/p\u003e \u003chr data-start=\"1178\" data-end=\"1181\" class=\"\"\u003e \u003ch5 data-start=\"1183\" data-end=\"1217\"\u003e\u003cstrong data-start=\"1187\" data-end=\"1217\"\u003eR-407C Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1219\" data-end=\"1416\"\u003e \u003cli data-start=\"1219\" data-end=\"1286\" class=\"\"\u003e \u003cp data-start=\"1221\" data-end=\"1286\" class=\"\"\u003e\u003cstrong data-start=\"1221\" data-end=\"1246\"\u003eChemical Composition:\u003c\/strong\u003e R-32 (23%), R-125 (25%), R-134a (52%)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1287\" data-end=\"1327\" class=\"\"\u003e \u003cp data-start=\"1289\" data-end=\"1327\" class=\"\"\u003e\u003cstrong data-start=\"1289\" data-end=\"1307\"\u003eBoiling Point:\u003c\/strong\u003e -43.6°C (-46.5°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1328\" data-end=\"1373\" class=\"\"\u003e \u003cp data-start=\"1330\" data-end=\"1373\" class=\"\"\u003e\u003cstrong data-start=\"1330\" data-end=\"1365\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 1,774\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1374\" data-end=\"1416\" class=\"\"\u003e \u003cp data-start=\"1376\" data-end=\"1416\" class=\"\"\u003e\u003cstrong data-start=\"1376\" data-end=\"1412\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1418\" data-end=\"1421\" class=\"\"\u003e \u003ch5 data-start=\"1423\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1427\" data-end=\"1448\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1450\" data-end=\"1601\" class=\"\"\u003e\u003cstrong data-start=\"1450\" data-end=\"1497\"\u003eResidential and Commercial Air Conditioning\u003c\/strong\u003e\u003cbr data-start=\"1497\" data-end=\"1500\"\u003ePerfect for central A\/C units, split systems, and packaged HVAC systems originally designed for R-22.\u003c\/p\u003e \u003cp data-start=\"1603\" data-end=\"1706\" class=\"\"\u003e\u003cstrong data-start=\"1603\" data-end=\"1617\"\u003eHeat Pumps\u003c\/strong\u003e\u003cbr data-start=\"1617\" data-end=\"1620\"\u003eFrequently used in both ducted and ductless heat pump systems for cooling and heating.\u003c\/p\u003e \u003cp data-start=\"1708\" data-end=\"1862\" class=\"\"\u003e\u003cstrong data-start=\"1708\" data-end=\"1728\"\u003eSystem Retrofits\u003c\/strong\u003e\u003cbr data-start=\"1728\" data-end=\"1731\"\u003eEngineered as a drop-in replacement in many older R-22 systems with minimal modifications (always consult manufacturer guidelines).\u003c\/p\u003e \u003chr data-start=\"1864\" data-end=\"1867\" class=\"\"\u003e \u003ch5 data-start=\"1869\" data-end=\"1912\"\u003e\u003cstrong data-start=\"1873\" data-end=\"1910\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1913\" data-end=\"2191\" class=\"\"\u003eR-407C remains a legal and practical solution for existing equipment as R-22 continues to be phased out. However, due to its moderate GWP, long-term transition toward even lower-GWP refrigerants is encouraged. Follow all local and national guidelines when handling refrigerants.\u003c\/p\u003e \u003chr data-start=\"2193\" data-end=\"2196\" class=\"\"\u003e \u003ch5 data-start=\"2198\" data-end=\"2213\"\u003e\u003cstrong data-start=\"2202\" data-end=\"2213\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2215\" data-end=\"2497\"\u003e \u003cli data-start=\"2215\" data-end=\"2276\" class=\"\"\u003e \u003cp data-start=\"2217\" data-end=\"2276\" class=\"\"\u003e\u003cstrong data-start=\"2217\" data-end=\"2231\"\u003ePackaging:\u003c\/strong\u003e Net Weight 11.3kg\/bottle (Net Weight 20.9lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2277\" data-end=\"2325\" class=\"\"\u003e \u003cp data-start=\"2279\" data-end=\"2325\" class=\"\"\u003e\u003cstrong data-start=\"2279\" data-end=\"2297\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2326\" data-end=\"2497\" class=\"\"\u003e \u003cp data-start=\"2328\" data-end=\"2497\" class=\"\"\u003e\u003cstrong data-start=\"2328\" data-end=\"2340\"\u003eStorage:\u003c\/strong\u003e Store in a dry, well-ventilated place. Avoid exposure to direct sunlight or temperatures above 52°C (125°F). Ensure proper labeling and leak-proof handling.\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562108297564,"sku":"PZ-407C","price":68.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/11_6e2b0b4e-0f1f-457d-99d8-aa8e63ba0c4d.jpg?v=1778108734"},{"product_id":"22lb-r454b-freon-refrigerant-gas","title":"22LB R454B R-454B Freon Refrigerant Gas","description":"\u003cp data-start=\"73\" data-end=\"457\"\u003e\u003cstrong data-start=\"73\" data-end=\"457\"\u003eR-454B is a next-generation refrigerant designed to replace R-410A in new HVAC systems. Offering similar performance with significantly lower environmental impact, it is the preferred low-GWP solution for air conditioning and heat pump manufacturers worldwide. As global regulations tighten, R-454B provides a reliable and future-compliant alternative for high-efficiency systems.\u003c\/strong\u003e\u003c\/p\u003e \u003chr data-start=\"459\" data-end=\"462\"\u003e \u003cp data-start=\"464\" data-end=\"493\"\u003e\u003cstrong data-start=\"464\" data-end=\"493\"\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e \u003cp data-start=\"495\" data-end=\"713\"\u003e✅ \u003cstrong data-start=\"497\" data-end=\"523\"\u003eUltra-Low GWP Solution\u003c\/strong\u003e\u003cbr data-start=\"523\" data-end=\"526\"\u003eWith a Global Warming Potential (GWP) of just \u003cstrong data-start=\"572\" data-end=\"579\"\u003e466\u003c\/strong\u003e, R-454B reduces climate impact by nearly \u003cstrong data-start=\"621\" data-end=\"628\"\u003e80%\u003c\/strong\u003e compared to R-410A (GWP ~2,088), helping meet international environmental standards.\u003c\/p\u003e \u003cp data-start=\"715\" data-end=\"886\"\u003e✅ \u003cstrong data-start=\"717\" data-end=\"749\"\u003eExcellent System Performance\u003c\/strong\u003e\u003cbr data-start=\"749\" data-end=\"752\"\u003eDelivers comparable capacity and energy efficiency to R-410A while enabling reduced charge sizes and better environmental credentials.\u003c\/p\u003e \u003cp data-start=\"888\" data-end=\"1060\"\u003e✅ \u003cstrong data-start=\"890\" data-end=\"917\"\u003eMild Flammability (A2L)\u003c\/strong\u003e\u003cbr data-start=\"917\" data-end=\"920\"\u003eClassified as \u003cstrong data-start=\"934\" data-end=\"941\"\u003eA2L\u003c\/strong\u003e – non-toxic and mildly flammable – suitable for use in new system designs built to handle low-GWP refrigerants safely.\u003c\/p\u003e \u003cp data-start=\"1062\" data-end=\"1219\"\u003e✅ \u003cstrong data-start=\"1064\" data-end=\"1087\"\u003eHVAC Industry Ready\u003c\/strong\u003e\u003cbr data-start=\"1087\" data-end=\"1090\"\u003eWidely adopted by major manufacturers for new air conditioning, rooftop units, VRF systems, and heat pumps. Not for retrofit use.\u003c\/p\u003e \u003chr data-start=\"1221\" data-end=\"1224\"\u003e \u003cp data-start=\"1226\" data-end=\"1256\"\u003e\u003cstrong data-start=\"1226\" data-end=\"1256\"\u003eR-454B Physical Properties\u003c\/strong\u003e\u003c\/p\u003e \u003cul data-start=\"1258\" data-end=\"1549\"\u003e \u003cli data-start=\"1258\" data-end=\"1318\"\u003e \u003cp data-start=\"1260\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1260\" data-end=\"1285\"\u003eChemical Composition:\u003c\/strong\u003e R-32 (68.9%), R-1234yf (31.1%)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1319\" data-end=\"1351\"\u003e \u003cp data-start=\"1321\" data-end=\"1351\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1343\"\u003eMolecular Formula:\u003c\/strong\u003e Blend\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1352\" data-end=\"1392\"\u003e \u003cp data-start=\"1354\" data-end=\"1392\"\u003e\u003cstrong data-start=\"1354\" data-end=\"1372\"\u003eBoiling Point:\u003c\/strong\u003e -54.4°C (-65.9°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1393\" data-end=\"1436\"\u003e \u003cp data-start=\"1395\" data-end=\"1436\"\u003e\u003cstrong data-start=\"1395\" data-end=\"1430\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 466\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1437\" data-end=\"1479\"\u003e \u003cp data-start=\"1439\" data-end=\"1479\"\u003e\u003cstrong data-start=\"1439\" data-end=\"1475\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1480\" data-end=\"1549\"\u003e \u003cp data-start=\"1482\" data-end=\"1549\"\u003e\u003cstrong data-start=\"1482\" data-end=\"1515\"\u003eASHRAE Safety Classification:\u003c\/strong\u003e A2L (Mildly Flammable, Non-Toxic)\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1551\" data-end=\"1554\"\u003e \u003cp data-start=\"1556\" data-end=\"1577\"\u003e\u003cstrong data-start=\"1556\" data-end=\"1577\"\u003eMain Applications\u003c\/strong\u003e\u003c\/p\u003e \u003cp data-start=\"1579\" data-end=\"1705\"\u003e\u003cstrong data-start=\"1579\" data-end=\"1618\"\u003eResidential \u0026amp; Light Commercial HVAC\u003c\/strong\u003e\u003cbr data-start=\"1618\" data-end=\"1621\"\u003eEngineered for new central air conditioning systems, mini-splits, and rooftop units.\u003c\/p\u003e \u003cp data-start=\"1707\" data-end=\"1819\"\u003e\u003cstrong data-start=\"1707\" data-end=\"1732\"\u003eCommercial Heat Pumps\u003c\/strong\u003e\u003cbr data-start=\"1732\" data-end=\"1735\"\u003eIdeal for high-efficiency buildings and environmentally compliant new installations.\u003c\/p\u003e \u003cp data-start=\"1821\" data-end=\"1911\"\u003e\u003cstrong data-start=\"1821\" data-end=\"1839\"\u003eVRF \u0026amp; Chillers\u003c\/strong\u003e\u003cbr data-start=\"1839\" data-end=\"1842\"\u003eOptimized for advanced system designs requiring low-GWP refrigerants.\u003c\/p\u003e \u003chr data-start=\"1913\" data-end=\"1916\"\u003e \u003cp data-start=\"1918\" data-end=\"1954\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1954\"\u003eNote on Environmental Compliance\u003c\/strong\u003e\u003c\/p\u003e \u003cp data-start=\"1956\" data-end=\"2257\"\u003eR-454B is compliant with current and upcoming F-Gas and AIM Act regulations. While it is not suitable for retrofitting R-410A systems, it plays a critical role in the global transition toward sustainable HVAC technology. Always follow certified A2L handling protocols and local regulations during use.\u003c\/p\u003e \u003chr data-start=\"2259\" data-end=\"2262\"\u003e \u003cp data-start=\"2264\" data-end=\"2275\"\u003e\u003cstrong data-start=\"2264\" data-end=\"2275\"\u003ePackage\u003c\/strong\u003e\u003c\/p\u003e \u003cul data-start=\"2277\" data-end=\"2505\"\u003e \u003cli data-start=\"2277\" data-end=\"2310\"\u003e \u003cp data-start=\"2279\" data-end=\"2310\"\u003e\u003cstrong data-start=\"2279\" data-end=\"2294\"\u003eNet Weight:\u003c\/strong\u003e 22lb (10kg)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2311\" data-end=\"2357\"\u003e \u003cp data-start=\"2313\" data-end=\"2357\"\u003e\u003cstrong data-start=\"2313\" data-end=\"2331\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel bottle\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2358\" data-end=\"2505\"\u003e \u003cp data-start=\"2360\" data-end=\"2505\"\u003e\u003cstrong data-start=\"2360\" data-end=\"2372\"\u003eStorage:\u003c\/strong\u003e Store upright in a cool, dry, and well-ventilated place. Avoid direct sunlight, open flames, or temperatures exceeding 52°C (125°F).\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562108559708,"sku":"pz-R454","price":650.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/1_050f662a-ac50-4e3b-bf37-aa20c2f23bc5.png?v=1778108735"},{"product_id":"r404a-freon-refrigerant","title":"24LB R404A R-404A Freon Refrigerant Gas","description":"\u003cp data-start=\"160\" data-end=\"505\" class=\"\"\u003eR-404A is a widely used HFC blend refrigerant, specifically formulated to deliver reliable, low-temperature cooling in commercial refrigeration systems. As a non-ozone depleting replacement for R-502 and CFC blends, R-404A is the industry standard for food storage, transport refrigeration, and other demanding low- and medium-temp applications.\u003c\/p\u003e \u003chr data-start=\"507\" data-end=\"510\" class=\"\"\u003e \u003ch5 data-start=\"512\" data-end=\"546\"\u003e\u003cstrong data-start=\"516\" data-end=\"546\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"548\" data-end=\"739\" class=\"\"\u003e✅ \u003cstrong data-start=\"550\" data-end=\"584\"\u003eSuperior low-temp performance:\u003c\/strong\u003e Designed to provide consistent cooling even at very low temperatures—ideal for frozen food storage, supermarket refrigeration, and refrigerated transport.\u003c\/p\u003e \u003cp data-start=\"741\" data-end=\"907\" class=\"\"\u003e✅ \u003cstrong data-start=\"743\" data-end=\"765\"\u003eR-502 replacement:\u003c\/strong\u003e Perfect retrofit solution for systems originally using R-502, offering comparable thermodynamic performance with better environmental safety.\u003c\/p\u003e \u003cp data-start=\"909\" data-end=\"1053\" class=\"\"\u003e✅ \u003cstrong data-start=\"911\" data-end=\"935\"\u003eNon-ozone depleting:\u003c\/strong\u003e R-404A contains no chlorine, giving it an ODP of 0 and meeting global environmental regulations for ozone protection.\u003c\/p\u003e \u003cp data-start=\"1055\" data-end=\"1199\" class=\"\"\u003e✅ \u003cstrong data-start=\"1057\" data-end=\"1082\"\u003eSystem compatibility:\u003c\/strong\u003e Works with synthetic lubricants such as POE oil, and compatible with many components designed for HFC-based systems.\u003c\/p\u003e \u003chr data-start=\"1201\" data-end=\"1204\" class=\"\"\u003e \u003ch5 data-start=\"1206\" data-end=\"1240\"\u003e\u003cstrong data-start=\"1210\" data-end=\"1240\"\u003eR-404A Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1242\" data-end=\"1438\"\u003e \u003cli data-start=\"1242\" data-end=\"1310\" class=\"\"\u003e \u003cp data-start=\"1244\" data-end=\"1310\" class=\"\"\u003e\u003cstrong data-start=\"1244\" data-end=\"1269\"\u003eChemical Composition:\u003c\/strong\u003e R-125 (44%), R-143a (52%), R-134a (4%)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1311\" data-end=\"1349\" class=\"\"\u003e \u003cp data-start=\"1313\" data-end=\"1349\" class=\"\"\u003e\u003cstrong data-start=\"1313\" data-end=\"1331\"\u003eBoiling Point:\u003c\/strong\u003e -46.1°C (-51°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1350\" data-end=\"1395\" class=\"\"\u003e \u003cp data-start=\"1352\" data-end=\"1395\" class=\"\"\u003e\u003cstrong data-start=\"1352\" data-end=\"1387\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 3,922\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1396\" data-end=\"1438\" class=\"\"\u003e \u003cp data-start=\"1398\" data-end=\"1438\" class=\"\"\u003e\u003cstrong data-start=\"1398\" data-end=\"1434\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1440\" data-end=\"1443\" class=\"\"\u003e \u003ch5 data-start=\"1445\" data-end=\"1470\"\u003e\u003cstrong data-start=\"1449\" data-end=\"1470\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1472\" data-end=\"1622\" class=\"\"\u003e\u003cstrong data-start=\"1472\" data-end=\"1512\"\u003eCommercial Freezers and Cold Storage\u003c\/strong\u003e\u003cbr data-start=\"1512\" data-end=\"1515\"\u003eIdeal for supermarket freezers, walk-in coolers, and industrial cold rooms requiring sub-zero temperatures.\u003c\/p\u003e \u003cp data-start=\"1624\" data-end=\"1762\" class=\"\"\u003e\u003cstrong data-start=\"1624\" data-end=\"1651\"\u003eTransport Refrigeration\u003c\/strong\u003e\u003cbr data-start=\"1651\" data-end=\"1654\"\u003eWidely used in refrigerated trucks, trailers, and containers where stable and powerful cooling is essential.\u003c\/p\u003e \u003cp data-start=\"1764\" data-end=\"1900\" class=\"\"\u003e\u003cstrong data-start=\"1764\" data-end=\"1790\"\u003eFood Service Equipment\u003c\/strong\u003e\u003cbr data-start=\"1790\" data-end=\"1793\"\u003eFound in ice cream machines, reach-in freezers, and frozen food display cabinets in restaurants and retail.\u003c\/p\u003e \u003chr data-start=\"1902\" data-end=\"1905\" class=\"\"\u003e \u003ch5 data-start=\"1907\" data-end=\"1950\"\u003e\u003cstrong data-start=\"1911\" data-end=\"1948\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1951\" data-end=\"2194\" class=\"\"\u003eDue to its high GWP, R-404A is subject to phasedown under HFC regulations in many regions. It remains a crucial refrigerant for servicing and maintaining legacy systems. Always ensure proper recovery and handling in compliance with local laws.\u003c\/p\u003e \u003chr data-start=\"2196\" data-end=\"2199\" class=\"\"\u003e \u003ch5 data-start=\"2201\" data-end=\"2216\"\u003e\u003cstrong data-start=\"2205\" data-end=\"2216\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2218\" data-end=\"2468\"\u003e \u003cli data-start=\"2218\" data-end=\"2279\" class=\"\"\u003e \u003cp data-start=\"2220\" data-end=\"2279\" class=\"\"\u003e\u003cstrong data-start=\"2220\" data-end=\"2234\"\u003ePackaging:\u003c\/strong\u003e Net Weight 10.9kg\/bottle (Net Weight 24lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2280\" data-end=\"2328\" class=\"\"\u003e \u003cp data-start=\"2282\" data-end=\"2328\" class=\"\"\u003e\u003cstrong data-start=\"2282\" data-end=\"2300\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2329\" data-end=\"2468\" class=\"\"\u003e \u003cp data-start=\"2331\" data-end=\"2468\" class=\"\"\u003e\u003cstrong data-start=\"2331\" data-end=\"2343\"\u003eStorage:\u003c\/strong\u003e Store in a cool, dry, and ventilated area. Keep away from heat sources and direct sunlight. Do not store above 52°C (125°F).\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562108789084,"sku":"PZ-404","price":68.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/1_1_ed732cd3-7e9f-4784-96e4-b98369736648.jpg?v=1778108736"},{"product_id":"25lb-r-407a-freon-refrigerant","title":"25LB R407A R-407A Freon Refrigerant Gas","description":"\u003cp data-start=\"174\" data-end=\"460\" class=\"\"\u003eR-407A is a high-performance HFC refrigerant blend developed as a lower GWP alternative to R-404A in commercial refrigeration applications. With comparable cooling capacity and improved energy efficiency, R-407A is widely used in supermarkets, cold storage, and food processing systems.\u003c\/p\u003e \u003chr data-start=\"462\" data-end=\"465\" class=\"\"\u003e \u003ch5 data-start=\"467\" data-end=\"501\"\u003e\u003cstrong data-start=\"471\" data-end=\"501\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"503\" data-end=\"722\" class=\"\"\u003e✅ \u003cstrong data-start=\"505\" data-end=\"531\"\u003eLower GWP than R-404A:\u003c\/strong\u003e R-407A offers a Global Warming Potential (GWP) of around 2,107—significantly lower than R-404A’s GWP of nearly 4,000—helping reduce environmental impact while maintaining strong performance.\u003c\/p\u003e \u003cp data-start=\"724\" data-end=\"906\" class=\"\"\u003e✅ \u003cstrong data-start=\"726\" data-end=\"756\"\u003eEfficient retrofit option:\u003c\/strong\u003e Suitable for converting existing R-404A systems with minor adjustments. Offers similar pressures and cooling characteristics for seamless transition.\u003c\/p\u003e \u003cp data-start=\"908\" data-end=\"1043\" class=\"\"\u003e✅ \u003cstrong data-start=\"910\" data-end=\"933\"\u003eNo ozone depletion:\u003c\/strong\u003e R-407A contains no chlorine and has a zero ODP, making it compliant with global ozone protection regulations.\u003c\/p\u003e \u003cp data-start=\"1045\" data-end=\"1181\" class=\"\"\u003e✅ \u003cstrong data-start=\"1047\" data-end=\"1075\"\u003eBroad application range:\u003c\/strong\u003e Delivers strong cooling performance in both low- and medium-temperature commercial refrigeration systems.\u003c\/p\u003e \u003chr data-start=\"1183\" data-end=\"1186\" class=\"\"\u003e \u003ch5 data-start=\"1188\" data-end=\"1222\"\u003e\u003cstrong data-start=\"1192\" data-end=\"1222\"\u003eR-407A Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1224\" data-end=\"1421\"\u003e \u003cli data-start=\"1224\" data-end=\"1291\" class=\"\"\u003e \u003cp data-start=\"1226\" data-end=\"1291\" class=\"\"\u003e\u003cstrong data-start=\"1226\" data-end=\"1251\"\u003eChemical Composition:\u003c\/strong\u003e R-32 (20%), R-125 (40%), R-134a (40%)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1292\" data-end=\"1332\" class=\"\"\u003e \u003cp data-start=\"1294\" data-end=\"1332\" class=\"\"\u003e\u003cstrong data-start=\"1294\" data-end=\"1312\"\u003eBoiling Point:\u003c\/strong\u003e -44.5°C (-48.1°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1333\" data-end=\"1378\" class=\"\"\u003e \u003cp data-start=\"1335\" data-end=\"1378\" class=\"\"\u003e\u003cstrong data-start=\"1335\" data-end=\"1370\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 2,107\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1379\" data-end=\"1421\" class=\"\"\u003e \u003cp data-start=\"1381\" data-end=\"1421\" class=\"\"\u003e\u003cstrong data-start=\"1381\" data-end=\"1417\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1423\" data-end=\"1426\" class=\"\"\u003e \u003ch5 data-start=\"1428\" data-end=\"1453\"\u003e\u003cstrong data-start=\"1432\" data-end=\"1453\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1455\" data-end=\"1592\" class=\"\"\u003e\u003cstrong data-start=\"1455\" data-end=\"1492\"\u003eSupermarket Refrigeration Systems\u003c\/strong\u003e\u003cbr data-start=\"1492\" data-end=\"1495\"\u003eDesigned for use in display cases, walk-in freezers, and other commercial food storage equipment.\u003c\/p\u003e \u003cp data-start=\"1594\" data-end=\"1748\" class=\"\"\u003e\u003cstrong data-start=\"1594\" data-end=\"1624\"\u003eCold Storage \u0026amp; Warehousing\u003c\/strong\u003e\u003cbr data-start=\"1624\" data-end=\"1627\"\u003ePerforms reliably in industrial cold rooms and low-temp storage facilities where consistent sub-zero cooling is required.\u003c\/p\u003e \u003cp data-start=\"1750\" data-end=\"1895\" class=\"\"\u003e\u003cstrong data-start=\"1750\" data-end=\"1779\"\u003eFood Processing Equipment\u003c\/strong\u003e\u003cbr data-start=\"1779\" data-end=\"1782\"\u003eSuitable for chillers, blast freezers, and processing lines where stable cooling is essential to product quality.\u003c\/p\u003e \u003chr data-start=\"1897\" data-end=\"1900\" class=\"\"\u003e \u003ch5 data-start=\"1902\" data-end=\"1945\"\u003e\u003cstrong data-start=\"1906\" data-end=\"1943\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1946\" data-end=\"2248\" class=\"\"\u003eR-407A is a strong transitional refrigerant for businesses looking to reduce environmental impact while maintaining performance. While not ultra-low GWP, its environmental footprint is substantially improved over legacy options like R-404A. Follow local guidelines for handling, recovery, and disposal.\u003c\/p\u003e \u003chr data-start=\"2250\" data-end=\"2253\" class=\"\"\u003e \u003ch5 data-start=\"2255\" data-end=\"2270\"\u003e\u003cstrong data-start=\"2259\" data-end=\"2270\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2272\" data-end=\"2534\"\u003e \u003cli data-start=\"2272\" data-end=\"2333\" class=\"\"\u003e \u003cp data-start=\"2274\" data-end=\"2333\" class=\"\"\u003e\u003cstrong data-start=\"2274\" data-end=\"2288\"\u003ePackaging:\u003c\/strong\u003e Net Weight 11.3kg\/bottle (Net Weight 25lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2334\" data-end=\"2382\" class=\"\"\u003e \u003cp data-start=\"2336\" data-end=\"2382\" class=\"\"\u003e\u003cstrong data-start=\"2336\" data-end=\"2354\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2383\" data-end=\"2534\" class=\"\"\u003e \u003cp data-start=\"2385\" data-end=\"2534\" class=\"\"\u003e\u003cstrong data-start=\"2385\" data-end=\"2397\"\u003eStorage:\u003c\/strong\u003e Store upright in a cool, dry, and ventilated area. Protect from physical damage, sunlight, and heat sources. Do not exceed 52°C (125°F).\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562109083996,"sku":"PZ-407A","price":199.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/R407A-6.jpg?v=1778108737"},{"product_id":"r410a-freon-refrigerant","title":"25LB R410A R-410A Freon Refrigerant Gas","description":"\u003cp data-start=\"161\" data-end=\"525\" class=\"\"\u003eR-410A, a near-azeotropic blend of HFC-32 and HFC-125, is the standard refrigerant in new residential and light commercial air conditioning systems. Known for its excellent energy efficiency and zero ozone depletion potential, R-410A is engineered to deliver superior performance in high-pressure systems, making it the go-to replacement for outdated R-22 systems.\u003c\/p\u003e \u003chr data-start=\"527\" data-end=\"530\" class=\"\"\u003e \u003ch5 data-start=\"532\" data-end=\"566\"\u003e\u003cstrong data-start=\"536\" data-end=\"566\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"568\" data-end=\"765\" class=\"\"\u003e✅ \u003cstrong data-start=\"570\" data-end=\"599\"\u003eEco-friendly composition:\u003c\/strong\u003e R-410A contains no chlorine, giving it an ODP of 0. It complies with global environmental standards and is safer for the ozone layer compared to legacy refrigerants.\u003c\/p\u003e \u003cp data-start=\"767\" data-end=\"925\" class=\"\"\u003e✅ \u003cstrong data-start=\"769\" data-end=\"797\"\u003eHigh cooling efficiency:\u003c\/strong\u003e Offers greater energy efficiency and better heat transfer capabilities than R-22, making it ideal for high-performance systems.\u003c\/p\u003e \u003cp data-start=\"927\" data-end=\"1081\" class=\"\"\u003e✅ \u003cstrong data-start=\"929\" data-end=\"967\"\u003eReliable in high-pressure systems:\u003c\/strong\u003e Designed to operate at higher pressures, R-410A supports more compact components and improved system performance.\u003c\/p\u003e \u003cp data-start=\"1083\" data-end=\"1232\" class=\"\"\u003e✅ \u003cstrong data-start=\"1085\" data-end=\"1106\"\u003eWidely supported:\u003c\/strong\u003e Compatible with modern HVAC equipment and synthetic lubricants (POE oil), ensuring easy servicing and component availability.\u003c\/p\u003e \u003chr data-start=\"1234\" data-end=\"1237\" class=\"\"\u003e \u003ch5 data-start=\"1239\" data-end=\"1273\"\u003e\u003cstrong data-start=\"1243\" data-end=\"1273\"\u003eR-410A Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1275\" data-end=\"1455\"\u003e \u003cli data-start=\"1275\" data-end=\"1325\" class=\"\"\u003e \u003cp data-start=\"1277\" data-end=\"1325\" class=\"\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1302\"\u003eChemical Composition:\u003c\/strong\u003e 50% R-32 \/ 50% R-125\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1326\" data-end=\"1366\" class=\"\"\u003e \u003cp data-start=\"1328\" data-end=\"1366\" class=\"\"\u003e\u003cstrong data-start=\"1328\" data-end=\"1346\"\u003eBoiling Point:\u003c\/strong\u003e -48.5°C (-55.3°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1367\" data-end=\"1412\" class=\"\"\u003e \u003cp data-start=\"1369\" data-end=\"1412\" class=\"\"\u003e\u003cstrong data-start=\"1369\" data-end=\"1404\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 2,088\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1413\" data-end=\"1455\" class=\"\"\u003e \u003cp data-start=\"1415\" data-end=\"1455\" class=\"\"\u003e\u003cstrong data-start=\"1415\" data-end=\"1451\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1457\" data-end=\"1460\" class=\"\"\u003e \u003ch5 data-start=\"1462\" data-end=\"1487\"\u003e\u003cstrong data-start=\"1466\" data-end=\"1487\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1489\" data-end=\"1659\" class=\"\"\u003e\u003cstrong data-start=\"1489\" data-end=\"1532\"\u003eResidential and Commercial HVAC Systems\u003c\/strong\u003e\u003cbr data-start=\"1532\" data-end=\"1535\"\u003eCommonly used in split-type air conditioners, central A\/C units, and packaged rooftop systems for both homes and businesses.\u003c\/p\u003e \u003cp data-start=\"1661\" data-end=\"1822\" class=\"\"\u003e\u003cstrong data-start=\"1661\" data-end=\"1693\"\u003eHeat Pumps and Dehumidifiers\u003c\/strong\u003e\u003cbr data-start=\"1693\" data-end=\"1696\"\u003ePreferred refrigerant for newer high-efficiency heat pump models and air treatment systems requiring reliable climate control.\u003c\/p\u003e \u003cp data-start=\"1824\" data-end=\"1935\" class=\"\"\u003e\u003cstrong data-start=\"1824\" data-end=\"1855\"\u003eNew Equipment Installations\u003c\/strong\u003e\u003cbr data-start=\"1855\" data-end=\"1858\"\u003eWidely adopted as the industry standard for systems built post-R-22 phaseout.\u003c\/p\u003e \u003chr data-start=\"1937\" data-end=\"1940\" class=\"\"\u003e \u003ch5 data-start=\"1942\" data-end=\"1985\"\u003e\u003cstrong data-start=\"1946\" data-end=\"1983\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1986\" data-end=\"2293\" class=\"\"\u003eWhile R-410A is ozone-friendly, its GWP is still significant. It is gradually being phased down in favor of next-generation refrigerants with lower environmental impact. For existing equipment, R-410A remains fully legal and essential for maintenance. Always adhere to local refrigerant handling guidelines.\u003c\/p\u003e \u003chr data-start=\"2295\" data-end=\"2298\" class=\"\"\u003e \u003ch5 data-start=\"2300\" data-end=\"2315\"\u003e\u003cstrong data-start=\"2304\" data-end=\"2315\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2317\" data-end=\"2566\"\u003e \u003cli data-start=\"2317\" data-end=\"2378\" class=\"\"\u003e \u003cp data-start=\"2319\" data-end=\"2378\" class=\"\"\u003e\u003cstrong data-start=\"2319\" data-end=\"2333\"\u003ePackaging:\u003c\/strong\u003e Net Weight 11.3kg\/bottle (Net Weight 25lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2379\" data-end=\"2427\" class=\"\"\u003e \u003cp data-start=\"2381\" data-end=\"2427\" class=\"\"\u003e\u003cstrong data-start=\"2381\" data-end=\"2399\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2428\" data-end=\"2566\" class=\"\"\u003e \u003cp data-start=\"2430\" data-end=\"2566\" class=\"\"\u003e\u003cstrong data-start=\"2430\" data-end=\"2442\"\u003eStorage:\u003c\/strong\u003e Store in a cool, dry, and shaded location. Avoid temperatures above 52°C (125°F). Handle with appropriate safety equipment.\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562109772124,"sku":"PZ-D41","price":68.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/1_1_6f61a5f7-64bd-4179-bdaf-9fe8dab1c4bd.jpg?v=1778108738"},{"product_id":"r22-freon-refrigerant","title":"30LB R22 R-22 Freon Refrigerant Gas","description":"\u003cp data-start=\"177\" data-end=\"586\" class=\"\"\u003eR-22, also known as Chlorodifluoromethane, has been the industry standard in residential and commercial HVAC systems for decades. While its production is being phased out due to environmental regulations, R-22 remains critical for servicing and maintaining millions of existing systems worldwide. With proven reliability and system compatibility, R-22 continues to support the performance of legacy equipment.\u003c\/p\u003e \u003chr data-start=\"588\" data-end=\"591\" class=\"\"\u003e \u003ch5 data-start=\"593\" data-end=\"627\"\u003e\u003cstrong data-start=\"597\" data-end=\"627\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"629\" data-end=\"803\" class=\"\"\u003e✅ \u003cstrong data-start=\"631\" data-end=\"664\"\u003eProven long-term performance:\u003c\/strong\u003e Decades of use in HVAC and refrigeration systems have established R-22 as one of the most stable and reliable refrigerants ever developed.\u003c\/p\u003e \u003cp data-start=\"805\" data-end=\"975\" class=\"\"\u003e✅ \u003cstrong data-start=\"807\" data-end=\"839\"\u003eLegacy system compatibility:\u003c\/strong\u003e Specifically designed for older systems, R-22 ensures seamless operation without the need for costly retrofitting or component changes.\u003c\/p\u003e \u003cp data-start=\"977\" data-end=\"1106\" class=\"\"\u003e✅ \u003cstrong data-start=\"979\" data-end=\"1007\"\u003eEfficient cooling power:\u003c\/strong\u003e Delivers consistent, powerful cooling performance in both residential and commercial environments.\u003c\/p\u003e \u003cp data-start=\"1108\" data-end=\"1251\" class=\"\"\u003e✅ \u003cstrong data-start=\"1110\" data-end=\"1132\"\u003eLow system stress:\u003c\/strong\u003e Operates under moderate pressure and works with traditional mineral oils, reducing wear and extending system lifespan.\u003c\/p\u003e \u003chr data-start=\"1253\" data-end=\"1256\" class=\"\"\u003e \u003ch5 data-start=\"1258\" data-end=\"1290\"\u003e\u003cstrong data-start=\"1262\" data-end=\"1290\"\u003eR-22 Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1292\" data-end=\"1504\"\u003e \u003cli data-start=\"1292\" data-end=\"1336\" class=\"\"\u003e \u003cp data-start=\"1294\" data-end=\"1336\" class=\"\"\u003e\u003cstrong data-start=\"1294\" data-end=\"1312\"\u003eChemical Name:\u003c\/strong\u003e Chlorodifluoromethane\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1337\" data-end=\"1370\" class=\"\"\u003e \u003cp data-start=\"1339\" data-end=\"1370\" class=\"\"\u003e\u003cstrong data-start=\"1339\" data-end=\"1361\"\u003eMolecular Formula:\u003c\/strong\u003e CHClF₂\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1371\" data-end=\"1411\" class=\"\"\u003e \u003cp data-start=\"1373\" data-end=\"1411\" class=\"\"\u003e\u003cstrong data-start=\"1373\" data-end=\"1391\"\u003eBoiling Point:\u003c\/strong\u003e -40.8°C (-41.4°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1412\" data-end=\"1457\" class=\"\"\u003e \u003cp data-start=\"1414\" data-end=\"1457\" class=\"\"\u003e\u003cstrong data-start=\"1414\" data-end=\"1449\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 1,810\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1458\" data-end=\"1504\" class=\"\"\u003e \u003cp data-start=\"1460\" data-end=\"1504\" class=\"\"\u003e\u003cstrong data-start=\"1460\" data-end=\"1496\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0.055\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1506\" data-end=\"1509\" class=\"\"\u003e \u003ch5 data-start=\"1511\" data-end=\"1536\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1536\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1538\" data-end=\"1699\" class=\"\"\u003e\u003cstrong data-start=\"1538\" data-end=\"1581\"\u003eResidential and Commercial HVAC Systems\u003c\/strong\u003e\u003cbr data-start=\"1581\" data-end=\"1584\"\u003ePerfect for older split systems, window A\/C units, rooftop units, and other equipment originally designed for R-22.\u003c\/p\u003e \u003cp data-start=\"1701\" data-end=\"1836\" class=\"\"\u003e\u003cstrong data-start=\"1701\" data-end=\"1726\"\u003eRefrigeration Systems\u003c\/strong\u003e\u003cbr data-start=\"1726\" data-end=\"1729\"\u003eStill widely used in walk-in coolers, ice machines, beverage storage, and food-service refrigeration units.\u003c\/p\u003e \u003cp data-start=\"1838\" data-end=\"1963\" class=\"\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1873\"\u003eChillers and Industrial Cooling\u003c\/strong\u003e\u003cbr data-start=\"1873\" data-end=\"1876\"\u003eSupports older industrial chillers and air-source heat pumps in large-scale facilities.\u003c\/p\u003e \u003chr data-start=\"1965\" data-end=\"1968\" class=\"\"\u003e \u003ch5 data-start=\"1970\" data-end=\"2013\"\u003e\u003cstrong data-start=\"1974\" data-end=\"2011\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"2014\" data-end=\"2270\" class=\"\"\u003eDue to its ozone depletion potential, R-22 is being phased out under international agreements. However, it remains legal for servicing existing systems in many regions. Always follow proper recovery, recycling, and handling protocols per local regulations.\u003c\/p\u003e \u003chr data-start=\"2272\" data-end=\"2275\" class=\"\"\u003e \u003ch5 data-start=\"2277\" data-end=\"2292\"\u003e\u003cstrong data-start=\"2281\" data-end=\"2292\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2294\" data-end=\"2545\"\u003e \u003cli data-start=\"2294\" data-end=\"2355\" class=\"\"\u003e \u003cp data-start=\"2296\" data-end=\"2355\" class=\"\"\u003e\u003cstrong data-start=\"2296\" data-end=\"2310\"\u003ePackaging:\u003c\/strong\u003e Net Weight 13.6kg\/bottle (Net Weight 30lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2356\" data-end=\"2404\" class=\"\"\u003e \u003cp data-start=\"2358\" data-end=\"2404\" class=\"\"\u003e\u003cstrong data-start=\"2358\" data-end=\"2376\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2405\" data-end=\"2545\" class=\"\"\u003e \u003cp data-start=\"2407\" data-end=\"2545\" class=\"\"\u003e\u003cstrong data-start=\"2407\" data-end=\"2419\"\u003eStorage:\u003c\/strong\u003e Store upright in a dry, cool, and well-ventilated area. Avoid heat sources, open flames, and temperatures above 52°C (125°F).\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562109804892,"sku":"PZ-22-ZU","price":68.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/1_4.jpg?v=1778108739"},{"product_id":"opteon™-xp44-r-452a-refrigerant-gas","title":"OPTEON™ XP44 (R-452A) R452a Refrigerant Gas","description":"\u003cp\u003e⚠️ Temporarily Out of Stock – We're currently restocking OPTEON™ XP44 (R-452A). Feel free to reach out to us for estimated availability or alternatives.\u003c\/p\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562110034268,"sku":"R-452A","price":500.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/452a.jpg?v=1778108740"},{"product_id":"r-422b-freon-refrigerant-gas","title":"R422B R-422B Freon Refrigerant Gas","description":"\u003cp\u003e⚠️ Temporarily Out of Stock – We're currently restocking R-422B. Feel free to reach out to us for estimated availability or alternatives.\u003c\/p\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562110067036,"sku":"R-422B","price":300.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/422b.jpg?v=1778108741"},{"product_id":"r134a-freon-refrigerant","title":"30LB R134A R-134A Freon Refrigerant Gas","description":"\u003cp data-start=\"185\" data-end=\"570\" class=\"\"\u003eR-134A, chemically known as 1,1,1,2-Tetrafluoroethane, has become a widely used refrigerant in automotive air conditioning systems and commercial refrigeration since the global phaseout of ozone-depleting substances. Its excellent thermodynamic properties and environmental safety compared to legacy refrigerants like R12 make it a go-to solution for a variety of cooling applications.\u003c\/p\u003e \u003chr data-start=\"572\" data-end=\"575\" class=\"\"\u003e \u003ch5 data-start=\"577\" data-end=\"611\"\u003e\u003cstrong data-start=\"581\" data-end=\"611\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"613\" data-end=\"820\" class=\"\"\u003e✅ \u003cstrong data-start=\"615\" data-end=\"646\"\u003eOzone-friendly performance:\u003c\/strong\u003e R-134A contains no chlorine and has zero ozone depletion potential (ODP), making it an environmentally safer option that complies with international environmental standards.\u003c\/p\u003e \u003cp data-start=\"822\" data-end=\"1026\" class=\"\"\u003e✅ \u003cstrong data-start=\"824\" data-end=\"853\"\u003eWide usage compatibility:\u003c\/strong\u003e Commonly used in automotive A\/C systems, commercial refrigeration units, and other medium-temperature applications. Ideal for both original equipment and retrofit projects.\u003c\/p\u003e \u003cp data-start=\"1028\" data-end=\"1181\" class=\"\"\u003e✅ \u003cstrong data-start=\"1030\" data-end=\"1054\"\u003eThermally efficient:\u003c\/strong\u003e Offers stable performance with good cooling efficiency and moderate operating pressures, reducing stress on system components.\u003c\/p\u003e \u003cp data-start=\"1183\" data-end=\"1352\" class=\"\"\u003e✅ \u003cstrong data-start=\"1185\" data-end=\"1212\"\u003eNon-flammable and safe:\u003c\/strong\u003e Classified as A1 by ASHRAE, R-134A is non-flammable and low toxicity, making it a safe and reliable choice for technicians and users alike.\u003c\/p\u003e \u003chr data-start=\"1354\" data-end=\"1357\" class=\"\"\u003e \u003ch5 data-start=\"1359\" data-end=\"1393\"\u003e\u003cstrong data-start=\"1363\" data-end=\"1393\"\u003eR-134A Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1395\" data-end=\"1607\"\u003e \u003cli data-start=\"1395\" data-end=\"1443\" class=\"\"\u003e \u003cp data-start=\"1397\" data-end=\"1443\" class=\"\"\u003e\u003cstrong data-start=\"1397\" data-end=\"1415\"\u003eChemical Name:\u003c\/strong\u003e 1,1,1,2-Tetrafluoroethane\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1444\" data-end=\"1477\" class=\"\"\u003e \u003cp data-start=\"1446\" data-end=\"1477\" class=\"\"\u003e\u003cstrong data-start=\"1446\" data-end=\"1468\"\u003eMolecular Formula:\u003c\/strong\u003e C₂H₂F₄\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1478\" data-end=\"1518\" class=\"\"\u003e \u003cp data-start=\"1480\" data-end=\"1518\" class=\"\"\u003e\u003cstrong data-start=\"1480\" data-end=\"1498\"\u003eBoiling Point:\u003c\/strong\u003e -26.3°C (-15.3°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1519\" data-end=\"1564\" class=\"\"\u003e \u003cp data-start=\"1521\" data-end=\"1564\" class=\"\"\u003e\u003cstrong data-start=\"1521\" data-end=\"1556\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 1,430\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1565\" data-end=\"1607\" class=\"\"\u003e \u003cp data-start=\"1567\" data-end=\"1607\" class=\"\"\u003e\u003cstrong data-start=\"1567\" data-end=\"1603\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1609\" data-end=\"1612\" class=\"\"\u003e \u003ch5 data-start=\"1614\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1618\" data-end=\"1639\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1641\" data-end=\"1761\" class=\"\"\u003e\u003cstrong data-start=\"1641\" data-end=\"1680\"\u003eAutomotive Air Conditioning Systems\u003c\/strong\u003e\u003cbr data-start=\"1680\" data-end=\"1683\"\u003eWidely used in passenger vehicles, trucks, and buses as a replacement for R12.\u003c\/p\u003e \u003cp data-start=\"1763\" data-end=\"1924\" class=\"\"\u003e\u003cstrong data-start=\"1763\" data-end=\"1804\"\u003eCommercial and Domestic Refrigeration\u003c\/strong\u003e\u003cbr data-start=\"1804\" data-end=\"1807\"\u003eIdeal for medium-temperature refrigeration such as beverage coolers, display cases, vending machines, and ice makers.\u003c\/p\u003e \u003cp data-start=\"1926\" data-end=\"2047\" class=\"\"\u003e\u003cstrong data-start=\"1926\" data-end=\"1958\"\u003eHeat Pumps and Dehumidifiers\u003c\/strong\u003e\u003cbr data-start=\"1958\" data-end=\"1961\"\u003eWorks effectively in appliances that require moderate-temperature cooling and heating.\u003c\/p\u003e \u003chr data-start=\"2049\" data-end=\"2052\" class=\"\"\u003e \u003ch5 data-start=\"2054\" data-end=\"2097\"\u003e\u003cstrong data-start=\"2058\" data-end=\"2095\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"2098\" data-end=\"2416\" class=\"\"\u003eWhile R-134A is ozone-friendly, its GWP is relatively high. Regulations in some regions are gradually restricting its use in certain new equipment. However, it remains a reliable and legal option for servicing and maintaining existing systems. Always follow regional and national guidelines when handling refrigerants.\u003c\/p\u003e \u003chr data-start=\"2418\" data-end=\"2421\" class=\"\"\u003e \u003ch5 data-start=\"2423\" data-end=\"2438\"\u003e\u003cstrong data-start=\"2427\" data-end=\"2438\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2440\" data-end=\"2683\"\u003e \u003cli data-start=\"2440\" data-end=\"2501\" class=\"\"\u003e \u003cp data-start=\"2442\" data-end=\"2501\" class=\"\"\u003e\u003cstrong data-start=\"2442\" data-end=\"2456\"\u003ePackaging:\u003c\/strong\u003e Net Weight 13.6kg\/bottle (Net Weight 30lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2502\" data-end=\"2550\" class=\"\"\u003e \u003cp data-start=\"2504\" data-end=\"2550\" class=\"\"\u003e\u003cstrong data-start=\"2504\" data-end=\"2522\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2551\" data-end=\"2683\" class=\"\"\u003e \u003cp data-start=\"2553\" data-end=\"2683\" class=\"\"\u003e\u003cstrong data-start=\"2553\" data-end=\"2565\"\u003eStorage:\u003c\/strong\u003e Store in a cool, dry, and well-ventilated area. Avoid exposure to direct sunlight or temperatures above 52°C (125°F).\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562140508508,"sku":"PZ-134","price":68.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/1_5_8191dbf4-6c59-4c71-a744-ee8d31353c42.jpg?v=1778108840"},{"product_id":"r-152a-freon-refrigerant-gas-lightweight-eco-friendly-freon","title":"R152a R-152a Freon Refrigerant Gas","description":"\u003cp\u003e⚠️ Temporarily Out of Stock – We're currently restocking OPTEON™ XP44 (R-452A). Feel free to reach out to us for estimated availability or alternatives.\u003c\/p\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562222264668,"sku":null,"price":500.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/010956def3c948358e1b05345650b3d6.jpg?v=1778109052"},{"product_id":"r-1234yf-freon-refrigerant","title":"R1234yf R-1234yf Freon Refrigerant Gas","description":"\u003cp\u003e⚠️ Temporarily Out of Stock – We're currently restocking OPTEON™ XP44 (R-452A). Feel free to reach out to us for estimated availability or alternatives.\u003c\/p\u003e","brand":"Frigster","offers":[{"title":"Default Title","offer_id":57562222788956,"sku":null,"price":999.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1009\/1967\/3180\/files\/1234yf25_600x_crop_center_7292df1c-ca8e-463b-aa86-6f65079b3927.jpg?v=1778109053"}],"url":"https:\/\/www.frigster.shop\/collections\/refrigerants.oembed","provider":"SOLINEY","version":"1.0","type":"link"}